HannYa 80L Thermal Shock Test Chamber Hot Zone And Cold Zone Separate Control (HY-TS-480)
Specifications
Details
HannYa 80L Thermal Shock Test Chamber Hot Zone And Cold Zone Separate Control
Machine introduction:
Programmable Environmental 2 Zone High Low Temperature Test Shock Chamber with Hot Zone and Cold Zone Separate Control is divided into two-box and three-box type, the difference is that the test method and internal structure are different, the product conforms to the standard: GB/T2423.1-2008 test A, GB/T2423.2-2008 test B, GB- T10592-2008, GJB150.3-198, GJB360A-96 Method
The hot and cold impact test box is a necessary test equipment for metal, plastics, rubber, electronics and other materials industries. It is used to test the structure of materials or composite materials, and can tolerance it under extremely high temperature and extremely low temperature in a continuous environment.
The chemical change or physical damage caused by thermal expansion and contraction of the sample can be detected in the shortest time.
Standards:
● GB-2423.1-89(IEC68-2-1)Test Mode A:Low Temperature Test
● GB-2423.2-89(IEC68-2-2)Test Mode B:High Temperature Test
● GJB360.8-87(MIL-STD.202F)High Temperature Life Test
● GBJl50.3(MIL-STD-810D)High Temperature Test
● GJBl50.4(MIL-STD-810D)Low Temperature Test
Product Descriptions
- The french import taikang compressor adopts the french taikang full-enclosed compressor, which is energy- saving, silent and high-efficient
- Programming with original import controller, clear digital, flexible touch, larga capacity SD recording, powerful function.
- Meet the test sample power, LED, power supply, digital industry preferred test chamber
- The condenser is surrounded by a closed design and the heat dissipation performance is very good
Specifications:
Model | HY-TS50 | HY-TS80 | HY-TS100 | HY-TS150 | HY-TS200 | HY-TS300 | HY-LY-TS480 | |
System | (BTC) Balanced temperature control system | |||||||
High temperature zone | +60℃~200℃ Optional | |||||||
Preheating time | +60℃~200℃ About 20 minutes | |||||||
Low temperature zone | -55℃~10℃, -70℃~10℃, -80℃~10℃ | |||||||
Precooling time | +20℃~-55℃ 60 minutes, +20℃~-75℃ 75 minutes, +20℃~-80℃ 90 minutes, | |||||||
Recovery time | Within 5 minutes, heat exposure 30 minutes, low exposure 30 minutes, | |||||||
Transfer time | Within 10 seconds | |||||||
Temperature flucturation | ±1.0℃ | |||||||
Temperature deviation | ≤±2.0℃ | |||||||
Interior dimension(cm) | W | 40 | 50 | 55 | 68 | 68 | 80 | 80 |
H | 40 | 40 | 45 | 45 | 50 | 50 | 55 | |
D | 32 | 40 | 40 | 50 | 60 | 75 | 93 | |
Test weight (KG) | 3.5 | 5 | 5 | 5 | 10 | 12 | 15 | |
Interior material | SUS#304 Stainless steel plate | |||||||
Exterior material | Backed paiting steel or stainless steel(SUS304) | |||||||
Insulation material | Rigid polyruethane foam +glass fibre | |||||||
Floor bearing load | 500Kg/m3 | |||||||
Refrigeration system | Air cooled (Water cooled type is option) | |||||||
Cascade type, hermetic/semitight compressor,CFC free refrigerant | ||||||||
Controller | Color LCD screen in English/Chinese, programing,communicating function | |||||||
Safety devices | No welding wire switch,compressor overheating and over current protection,over temperature protection, blower overload protection,dry heating machine protector,low water protection,fault warning system. | |||||||
Power | AC380±10% 50HZ 3 phase 4 wires+ground wires |